The Butyl Products' range of demountable water storage tanks were initially developed in the 1960s to meet the demand for economical water storage in the agriculture and horticulture industries. They soon found uses in manufacturing for storing firewater and process liquids.
Initially designed for short term use, the tanks are now often used for long term liquid storage and an application life of 20 years is not uncommon.
The tanks need no base structure so they can be built on any flat ground.
Suitable for all climates.
Erected by 3 people within 8 hours.
| Tank Diameter | Tank Overall Height | Roof Option |
metres |
1.53m |
2.29m |
3.05m |
PVC |
Steel |
Denotes capacity in litres allowing for 0.15m freeboard |
2.74 |
8,138 |
12,619 |
17,100 |
||
3.66 |
14,519 |
22,515 |
30,510 |
||
4.57 |
22,637 |
35,102 |
47,569 |
||
5.49 |
32,667 |
50,658 |
68,649 |
||
6.40 |
44,395 |
68,843 |
93,293 |
||
7.32 |
58,075 |
90,058 |
122,042 |
||
8.23 |
73,412 |
113,842 |
154,272 |
||
9.15 |
90,743 |
140,717 |
|||
10.06 |
109,689 |
151,363 |
|||
10.98 |
130,668 |
202,632 |
Click here to download the large tank installation instructions
Click here to download the small tank installation instructions
Tank Body
The main tank structure comprises 0.80m wide x 3.05m long panels of corrugated galvanised steel which are punched and curved to suit the tank size. Galvanised round headed bolts with washers and nuts are provided to assemble the steel panels to form a ring of the required diameter and height. The top edge of the steel is protected by a circular plastic capping piece.
![]() Installing Liner |
Tank Lining The lining comprises a fully welded watertight bag sized to suit the tank. Liners are manufactured in a range of materials and a range of thicknesses to suit the required application. The liner is held in position at the top of the tank by clamping between two capping pieces and locking in position using spring clips. |
![]() 3" BSP (M) through tank outlet with 3" BSP (F) gate valve fitted. |
Tank Fittings 3" BSP (M) through tank outlets are provided. The outlets are bolted to the tank body and sealed to the tank lining. 3" BSP (F) gate valves and ball valves are available for use with these outlets. Other size outlets can be supplied. The position and number of outlets is decided by the customer. |
Tank Roofs
The tanks can be used open top or with either of the following roofs.
PVC roof
Ideal for keeping dirt out of the tank. These economical roofs have a 3 year life and can be erected in 1 hour. NOTE: The PVC roofs will not hold snow and are not suitable for exposed locations if high winds are common.
Steel roofs:
Produced from galvanised sheet steel, with a lockable manway, these are bolted to the tank and are suitable for all environments and where tank security is paramount. Steel roofs are installed in approximately 4 hours.

Spares
A full range of spares and accessories are available ex stock.